Technical Specifications
| Specification | Details |
|---|---|
| Laser Wavelengths | 755 / 808 / 1064 nm (Customizable) |
| Spot Size | 15 × 25 mm / 15 × 35 mm (Optional) |
| Diode Laser Energy | 1–150 J |
| Pulse Frequency | 1–10 Hz |
| Pulse Width | 1–400 ms |
| Nd Laser Energy | 0.4–2.0 J |
| Display | 10.4-inch Color Touchscreen |
| Cooling System | Radiator Cooling System |
| Temperature Alarm | Adjustable, 10–60°C (50–140°F) |
| Water Flow Alarm | 2 L/min |
| Power Supply | AC 120 V / 230 V, 50/60 Hz (Region-Specific Options) |
| Machine Dimensions (L × W × H) | 16.9 × 25.0 × 19.1 in (43 × 63.5 × 48.5 cm) |
| Machine Weight | 40 kg (88.2 lb) |
How It Works
1. Triple-Wavelength Diode Laser Hair Removal
The diode laser system uses three wavelengths—755nm, 808nm, and 1064nm—to support professional hair removal treatments. Melanin in the hair absorbs laser energy, which is converted into heat to target hair follicles and help reduce hair growth over a series of treatments.
2. Nd:YAG Laser Tattoo Removal
The integrated Nd laser supports professional tattoo pigment removal using wavelength options available in the installed configuration. Different wavelengths interact with tattoo pigments differently.
3 Treatment Modes
HR Mode — High-Energy Pulse Mode
HR mode delivers a single high-energy laser pulse with each emission, providing a targeted approach to professional hair removal. This mode allows practitioners to apply individual pulses to selected treatment areas, offering an alternative to the rapid, repeated pulse sequences used in SHR and SHR STACK modes.
Practitioners can adjust fluence and repetition frequency through the machine’s operating interface according to the selected treatment protocol.
SHR Mode — Super Hair Removal Mode
SHR mode delivers a series of lower-energy laser pulses in rapid succession, supporting continuous-gliding treatment techniques for professional hair removal. Rather than relying on individual high-energy pulses, this mode uses a sequence of rapid pulses to provide an alternative approach to hair removal treatments.
Practitioners can adjust fluence, pulse width, and frequency according to the machine’s operating interface, selected treatment protocol, and individual client needs. These adjustable parameters offer flexibility .
SHR STACK Mode — Pulse-Stacking Mode
SHR STACK mode delivers a sequence of laser pulses in rapid succession, allowing practitioners to use a pulse-stacking approach for selected professional hair removal applications. This mode provides an alternative to single-pulse delivery and the continuous-gliding approach used in other operating modes.
Practitioners can adjust fluence and frequency through the machine’s operating interface according to the selected treatment protocol. The fluence adjustment increments in SHR STACK mode differ from those in SHR mode, giving operators another way to fine-tune treatment parameters within the machine’s available settings.
Before & After Results
Underarm Hair Reduction
Helps reduce unwanted underarm hair for smoother-looking skin.
Arm & Leg Hair Reduction
Helps reduce unwanted arm and leg hair for smoother-looking skin.
Back & Body Hair Reduction
Helps reduce unwanted body hair for smoother-looking skin.
Tattoo Pigment Removal
Helps fade unwanted tattoo pigments for clearer-looking skin.
Permanent Makeup Removal
Helps fade unwanted eyebrow tattoo pigments for a natural look.
Pigmentation Treatments
Helps fade unwanted skin pigmentation for a more natural look.
Machine Components
Package Includes
1.Main Machine
2.Nd:YAG Laser Handpiece
3.Diode Laser Handpiece
4.Protective Goggles
5.Protective Glasses
6.Power Cable
7.Water Filling Funnel
3-Year Warranty & Support
-
3-Year Warranty: Warranty coverage begins upon confirmed delivery.
- Replacement Parts: Spare parts and accessories are available upon request.
Shipping & Delivery
-
Sea Freight Only: All international orders are shipped via sea freight.
-
Secure Packaging: Carefully packaged to help protect the equipment from damage during transportation.
FAQ
Yes. The machine allows operators to save preferred treatment parameters for convenient access during future sessions. Available settings depend on the selected treatment mode.
Use distilled water in the cooling system. Follow the manufacturer’s instructions for water filling, replacement, drainage, and routine maintenance to help maintain proper cooling performance.
Before operation, ensure the handpieces are properly connected, fill the cooling system with distilled water as instructed in the manufacturer’s manual, and check that water circulation is functioning correctly. Operators should also verify the machine settings and use appropriate laser protective eyewear before treatment.
Handpiece maintenance and replacement intervals depend on usage, operating conditions, and the manufacturer’s specifications. Inspect the handpieces regularly and follow the recommended maintenance procedures.
Stop treatment and check the cooling system according to the manufacturer’s instructions. For a water-flow alarm, inspect the water tubing and connections and verify that the pump is operating correctly. For a temperature alarm, allow the cooling water to return to the recommended operating range before resuming use.